Refine
Year of publication
Document Type
- Article (68)
- Preprint (35)
- Doctoral Thesis (1)
- Part of Periodical (1)
Has Fulltext
- yes (105)
Is part of the Bibliography
- no (105)
Keywords
- Mammakarzinom (12)
- breast cancer (12)
- Behandlung (8)
- Metastasen (8)
- CDK4/6 (6)
- PD1/PDL1 (6)
- Prävention (6)
- Studien (6)
- prevention (6)
- treatment (6)
- metastases (5)
- LHC (4)
- Risiko (4)
- risk (4)
- trials (4)
- ALICE experiment (3)
- Hadron-Hadron Scattering (3)
- metastatic (3)
- pp collisions (3)
- Alpelisib (2)
- Atezolizumab (2)
- Beauty production (2)
- Brain metastasis (2)
- Diagnostik (2)
- Früherkennung (2)
- Galaktografie (2)
- Galaktomosynthese (2)
- Katherine (2)
- Lokalrezidiv (2)
- MRI (2)
- MRT (2)
- Mamma (2)
- Nachsorge (2)
- PARP (2)
- PD1/ PDL1 (2)
- PD‑L1 (2)
- PI3K (2)
- Prognosefaktoren (2)
- Prädiktivfaktoren (2)
- Richtlinie (2)
- Single electrons (2)
- Supportivtherapie (2)
- Tomosynthese (2)
- T‑DM1 (2)
- Ultraschall (2)
- adjuvant therapy (2)
- adjuvante Therapie (2)
- advanced (2)
- alpelisib (2)
- atezolizumab (2)
- breast (2)
- diagnosis (2)
- early breast cancer (2)
- follow‑up (2)
- fortgeschritten (2)
- frühes Mammakarzinom (2)
- galactography (2)
- galactomosynthesis (2)
- guideline (2)
- local recurrence (2)
- neoadjuvant therapy (2)
- neoadjuvante Therapie (2)
- predictive factors (2)
- prognostic factors (2)
- screening (2)
- studies (2)
- supportive therapy (2)
- tomosynthesis (2)
- treatment/therapy (2)
- ultrasound (2)
- ALICE (1)
- Acetobacterium woodii (1)
- Amber inclusion (1)
- BBB (1)
- Biohydrogen (1)
- Breast cancer (1)
- CD74 (1)
- Charm physics (1)
- Comparison with QCD (1)
- Docetaxel (1)
- EP300 (1)
- EWSR1 (1)
- FOXO1 (1)
- Formate dehydrogenase (1)
- Gene fusion (1)
- HER2 c-erbB2 (1)
- HER2/neu (1)
- HLA class II (1)
- HLA peptidome (1)
- Hadron production (1)
- Heavy Ions (1)
- Heavy flavor production (1)
- Heavy flavour production (1)
- Heavy ions (1)
- Heavy-flavour production (1)
- Hydrogen production (1)
- Hydrogenase (1)
- Inclusive spectra (1)
- Jets (1)
- Mid-Cretaceous (1)
- Mid-rapidity (1)
- Multi-strange baryons (1)
- Myanmar (1)
- Neuroepithelial tumor (1)
- PLAGL1 (1)
- Proton–proton (1)
- Red blood cell transfusion (1)
- Relativistic heavy ion physics (1)
- Single muons (1)
- Supratentorial (1)
- T-DM1 (1)
- TEER (1)
- Taxane (1)
- Tumor infiltrating lymphocytes (1)
- advanced breast cancer (1)
- anaemia (1)
- antihormone therapy (1)
- aquatic insects (1)
- chemotherapy (1)
- elderly patients (1)
- freshwater (1)
- iron deficiency (1)
- lapatinib (1)
- metastasis (1)
- patient blood management (1)
- pertuzumab (1)
- preoperative anaemia management (1)
- spectra (1)
- surgery (1)
- trastuzumab (1)
Institute
Ziele: Das Ziel dieser offiziellen Leitlinie, die von der Deutschen Gesellschaft für Gynäkologie und Geburtshilfe (DGGG) und der Deutschen Krebsgesellschaft (DKG) publiziert und koordiniert wurde, ist es, die Früherkennung, Diagnostik, Therapie und Nachsorge des Mammakarzinoms zu optimieren.
Methoden: Der Aktualisierungsprozess der S3-Leitlinie aus 2012 basierte zum einen auf der Adaptation identifizierter Quellleitlinien und zum anderen auf Evidenzübersichten, die nach Entwicklung von PICO-(Patients/Interventions/Control/Outcome-)Fragen, systematischer Recherche in Literaturdatenbanken sowie Selektion und Bewertung der gefundenen Literatur angefertigt wurden. In den interdisziplinären Arbeitsgruppen wurden auf dieser Grundlage Vorschläge für Empfehlungen und Statements erarbeitet, die im Rahmen von strukturierten Konsensusverfahren modifiziert und graduiert wurden.
Empfehlungen: Der Teil 1 dieser Kurzversion der Leitlinie zeigt Empfehlungen zur Früherkennung, Diagnostik und Nachsorge des Mammakarzinoms: Der Stellenwert des Mammografie-Screenings wird in der aktualisierten Leitlinienversion bestätigt und bildet damit die Grundlage der Früherkennung. Neben den konventionellen Methoden der Karzinomdiagnostik wird die Computertomografie (CT) zum Staging bei höherem Rückfallrisiko empfohlen. Die Nachsorgekonzepte beinhalten Untersuchungsintervalle für die körperliche Untersuchung, Ultraschall und Mammografie, während weiterführende Gerätediagnostik und Tumormarkerbestimmungen bei der metastasierten Erkrankung Anwendung finden.
Purpose: The aim of this official guideline coordinated and published by the German Society for Gynecology and Obstetrics (DGGG) and the German Cancer Society (DKG) was to optimize the screening, diagnosis, therapy and follow-up care of breast cancer.
Methods: The process of updating the S3 guideline dating from 2012 was based on the adaptation of identified source guidelines which were combined with reviews of evidence compiled using PICO (Patients/Interventions/Control/Outcome) questions and the results of a systematic search of literature databases and the selection and evaluation of the identified literature. The interdisciplinary working groups took the identified materials as their starting point to develop recommendations and statements which were modified and graded in a structured consensus procedure.
Recommendations: Part 1 of this short version of the guideline presents recommendations for the screening, diagnosis and follow-up care of breast cancer. The importance of mammography for screening is confirmed in this updated version of the guideline and forms the basis for all screening. In addition to the conventional methods used to diagnose breast cancer, computed tomography (CT) is recommended for staging in women with a higher risk of recurrence. The follow-up concept includes suggested intervals between physical, ultrasound and mammography examinations, additional high-tech diagnostic procedures, and the determination of tumor markers for the evaluation of metastatic disease.
Transverse momentum spectra of π±, K± and p(p¯) up to pT = 20 GeV/c at mid-rapidity in pp and Pb-Pb collisions at sNN−−−√= 2.76 TeV have been measured using the ALICE detector at the Large Hadron Collider. The proton-to-pion and the kaon-to-pion ratios both show a distinct peak at pT≈3GeV/c in central Pb-Pb collisions. Below the peak, pT < 3 GeV/c, both ratios are in good agreement with hydrodynamical calculations, suggesting that the peak itself is dominantly the result of radial flow rather than anomalous hadronization processes. For pT > 10 GeV/c particle ratios in pp and Pb-Pb collisions are in agreement and the nuclear modification factors for π±, K± and p(p¯) indicate that, within the systematic and statistical uncertainties, the suppression is the same. This suggests that the chemical composition of leading particles from jets in the medium is similar to that of vacuum jets.
Long-range angular correlations on the near and away side in p–Pb collisions at √sNN=5.02 TeV
(2013)
Angular correlations between charged trigger and associated particles are measured by the ALICE detector in p–Pb collisions at a nucleon–nucleon centre-of-mass energy of 5.02 TeV for transverse momentum ranges within 0.5<pT,assoc<pT,trig<4 GeV/c. The correlations are measured over two units of pseudorapidity and full azimuthal angle in different intervals of event multiplicity, and expressed as associated yield per trigger particle. Two long-range ridge-like structures, one on the near side and one on the away side, are observed when the per-trigger yield obtained in low-multiplicity events is subtracted from the one in high-multiplicity events. The excess on the near-side is qualitatively similar to that recently reported by the CMS Collaboration, while the excess on the away-side is reported for the first time. The two-ridge structure projected onto azimuthal angle is quantified with the second and third Fourier coefficients as well as by near-side and away-side yields and widths. The yields on the near side and on the away side are equal within the uncertainties for all studied event multiplicity and pT bins, and the widths show no significant evolution with event multiplicity or pT. These findings suggest that the near-side ridge is accompanied by an essentially identical away-side ridge.
Background and objectives: Preoperative anaemia is an independent risk factor for a higher morbidity and mortality, a longer hospitalization and increased perioperative transfusion rates. Managing preoperative anaemia is the first of three pillars of Patient Blood Management (PBM), a multidisciplinary concept to improve patient safety. While various studies provide medical information on (successful) anaemia treatment pathways, knowledge of organizational details of diagnosis and management of preoperative anaemia across Europe is scarce.
Materials and methods: To gain information on various aspects of preoperative anaemia management including organization, financing, diagnostics and treatment, we conducted a survey (74 questions) in ten hospitals from seven European nations within the PaBloE (Patient Blood Management in Europe) working group covering the year 2016.
Results: Organization and activity in the field of preoperative anaemia management were heterogeneous in the participating hospitals. Almost all hospitals had pathways for managing preoperative anaemia in place, however, only two nations had national guidelines. In six of the ten participating hospitals, preoperative anaemia management was organized by anaesthetists. Diagnostics and treatment focused on iron deficiency anaemia which, in most hospitals, was corrected with intravenous iron.
Conclusion: Implementation and approaches of preoperative anaemia management vary across Europe with a primary focus on treating iron deficiency anaemia. Findings of this survey motivated the hospitals involved to critically evaluate their practice and may also help other hospitals interested in PBM to develop action plans for diagnosis and management of preoperative anaemia.
A measurement of the transverse momentum spectra of jets in Pb-Pb collisions at sNN−−−√=2.76 TeV is reported. Jets are reconstructed from charged particles using the anti-kT jet algorithm with jet resolution parameters R of 0.2 and 0.3 in pseudo-rapidity |η|<0.5. The transverse momentum pT of charged particles is measured down to 0.15 GeV/c which gives access to the low pT fragments of the jet. Jets found in heavy-ion collisions are corrected event-by-event for average background density and on an inclusive basis (via unfolding) for residual background fluctuations and detector effects. A strong suppression of jet production in central events with respect to peripheral events is observed. The suppression is found to be similar to the suppression of charged hadrons, which suggests that substantial energy is radiated at angles larger than the jet resolution parameter R=0.3 considered in the analysis. The fragmentation bias introduced by selecting jets with a high pT leading particle, which rejects jets with a soft fragmentation pattern, has a similar effect on the jet yield for central and peripheral events. The ratio of jet spectra with R=0.2 and R=0.3 is found to be similar in Pb-Pb and simulated PYTHIA pp events, indicating no strong broadening of the radial jet structure in the reconstructed jets with R<0.3.
Three new fossil species from Burmese amber are described, one clearly in family Calamoceratidae, the other two in the highly variable family Odontoceridae. The family Odontoceridae contains 18 disparate genera, but there are no good diagnostic characters, which makes it difficult to place fossil taxa in this family. We here offer a revised diagnosis for the family, highlighting the lack of good diagnostic characters, and the need to use sets of characters to place (extinct) taxa in this family. On this taxonomic basis we describe two new species in the hitherto monotypic fossil genus Palaeopsilotreta Wichard & Wang, 2017 (Odontoceridae), Palaeopsilotreta burmanica sp. nov. and P. cretacea sp. nov., redescribe the type species based on additional information, and describe features of the female, based on two specimens, one of which is embedded adjacent to a male identified as P. xiai. Males of Palaeopsilotreta bear bipectinate antennae; the antennae of the females are simple and filiform. Similarly, bipectinate antennae are present in the third species we describe, Bipectinata orientalis gen. et sp. nov., which otherwise lacks the character combinations associated with the Odontoceridae, but clearly can be assigned to the family Calamoceratidae.
Einleitung: Die konventionelle Galaktografie stellte jahrzehntelang das einzige bildgebende Verfahren zur Darstellung von Milchgängen in der Brust dar. Heute verfügen wir in der Diagnostik über ein multimodales Konzept aus hochauflösendem Ultraschall, der Magnetresonanz-(MR-)Mammografie und der Duktoskopie/Galaktoskopie mit Sensitivitäten und Spezifitäten bis zu 95%. Ziel unserer Untersuchung war es, erstmalig die Tomosynthesetechnik in der Galaktografie einzusetzen und die daraus generierten synthetischen digitalen 2-D-Vollfeld-Mammografien mit der etablierten Methode der duktusorientierten Sonografie zu vergleichen. Es sollen mit beiden Methoden invasive Mammakarzinome und deren Vorstufen wie duktale Carcinoma in situ (DCIS) sowie benigne Befunde erkannt werden. Material und Methoden: Wir führten bei 5 Patientinnen mit pathologischer Mamillensekretion sowohl eine duktusorientierte Sonografie, eine kontrastmittelunterstützte Galaktografie mithilfe der Tomosynthese in 3-D sowie auch den daraus generierten synthetischen digitalen 2-D-Vollfeld-Mammografien durch. Die Auswertung der unterschiedlichen Untersuchungsmodalitäten erfolgte durch 3 in der komplementären Mammadiagnostik erfahrene Untersucher (1, 5 und 15 Jahre) und wurde mit der endgültigen Histologie korreliert. Ergebnisse: Alle 3 Untersucher beurteilten unabhängig voneinander die Bilder des duktusorientierten Ultraschalls und der kontrastmittelunterstützten Galaktografie in Tomosynthesetechnik in 3-D und den daraus generierten, synthetischen digitalen 2-D-Vollfeld-Mammografien. Die Ergebnisse wurden mit den histopathologischen Befunden der Operationspräparate korreliert, wobei sich bei den 5 Patientinnen 1 invasives Mammakarzinom, 2-mal ein duktales Carcinoma in situ (DCIS) und 2 benigne Befunde ergaben. Alle drei Untersucher lagen bei der Verdachtsdiagnose in der Standardbildgebung der duktusorientierten Sonografie seltener richtig als bei der erstmalig durchgeführten, kontrastmittelunterstützten Galaktografie in Tomosynthesetechnik und den daraus generierten, synthetischen digitalen 2-D-Vollfeld-Mammografien. Schlussfolgerung: Erstmalig wurde die Brusttomosynthese in der Galaktografie (Galaktomosynthese) eingesetzt und ermöglichte eine digitale, 3-dimensionale Darstellung von suspekten Befunden. Zusammen mit den daraus synthetisierten, digitalen 2-D-Vollfeld-Mammografien könnte dies in Zukunft eine sinnvolle Ergänzung der komplementären Mammadiagnostik sein – und eine Renaissance dieser Methode. Im Vergleich mit dem duktusorientierten Ultraschall in Hochauflösung erzielten die Untersucher mit der kontrastmittelunterstützten Galaktografie in Tomosynthesetechnik und den daraus generierten, synthetischen digitalen 2-D-Vollfeld-Mammografien bessere Ergebnisse in Korrelation mit den histopathologischen Befunden.
Introduction: For decades, conventional galactography was the only imaging technique capable of showing the mammary ducts. Today, diagnosis is based on a multimodal concept which combines high-resolution ultrasound with magnetic resonance (MR) mammography and ductoscopy/galactoscopy and has a sensitivity and specificity of up to 95%. This study used tomosynthesis in galactography for the first time and compared the synthetic digital 2D full-field mammograms generated with this technique with the images created using the established method of ductal sonography. Both methods should be able to detect invasive breast cancers and their precursors such as ductal carcinoma in situ (DCIS) as well as being able to identify benign findings.
Material and Methods: Five patients with pathological nipple discharge were examined using ductal sonography, contrast-enhanced 3D galactography with tomosynthesis and the synthetic digital 2D full-field mammograms generated with the latter method. Evaluation of the images created with the different imaging modalities was done by three investigators with varying levels of experience with complementary breast diagnostics (1, 5 and 15 years), and their evaluations were compared with the histological findings.
Results: All 3 investigators independently evaluated the images created with ductal sonography, contrast-enhanced 3D galactography with tomosynthesis, and generated synthetic digital 2D full-field mammograms. Their evaluations were compared with the histopathological assessment of the surgical specimens resected from the 5 patients. There was 1 case of invasive breast cancer, 2 cases with ductal carcinoma in situ and 2 cases with benign findings. All 3 investigators made more mistakes when they used the standard imaging technique of ductal sonography to diagnose suspicious lesions than when they used contrast-enhanced galactography with tomosynthesis and the generated synthetic digital 2D full-field mammograms.
Conclusion: This is the first time breast tomosynthesis was used in galactography (galactomosynthesis) to create digital 3-dimensional images of suspicious findings. When used together with the generated synthetic digital 2D full-field mammograms, it could be a useful complementary procedure for the diagnosis of breast anomalies and could herald a renaissance of this method. Compared with high-resolution ductal ultrasound, the investigators achieved better results with contrast-enhanced galactography using tomosynthesis and the generated synthetic digital 2D full-field mammograms, as confirmed by histopathological findings.
Neue Therapieentwicklungen zur Behandlung von Patientinnen mit fortgeschrittenem Mammakarzinom konzentrieren sich zurzeit sowohl auf die Identifikation von Patientinnen für zielgerichtete Therapieansätze als auch auf die Weiterentwicklung von immuntherapeutischen Ansätzen. Die Datenlage zu den CDK4/6-Inhibitoren konnte vervollständigt werden und ist konsistent in dieser Klasse von Substanzen (Palbociclib, Ribociclib und Abemaciclib). Weitere Signalwege, die untersucht werden, sind der PI3K-und der AKT-Signalweg sowie verschiedene Ansatzpunkte zu deren Hemmung. Für beide Wirkmechanismen liegen auch erste Studienergebnisse vor, die vor Kurzem vorgestellt wurden. Außerdem wachsen die Erkenntnisse zu den PARP-Inhibitoren, für die auch untersucht wird, in welcher Population sie am effektivsten eingesetzt werden können. Dieser Review-Artikel soll die aktuellen Studien zusammenfassen und einen Ausblick der neuesten Entwicklungen geben.