Refine
Year of publication
Document Type
- Preprint (685)
- Article (407)
- Book (2)
- Conference Proceeding (2)
- Working Paper (1)
Has Fulltext
- yes (1097)
Is part of the Bibliography
- no (1097)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (10)
- Heavy-ion collision (6)
- ALICE experiment (4)
- Collective Flow (4)
- Jets (4)
- Kollisionen schwerer Ionen (4)
- Quark-Gluon Plasma (4)
Institute
- Physik (1058)
- Frankfurt Institute for Advanced Studies (FIAS) (961)
- Informatik (924)
- Medizin (24)
- Biochemie und Chemie (6)
- Hochschulrechenzentrum (3)
- Informatik und Mathematik (3)
- Biowissenschaften (2)
- MPI für Biophysik (2)
- Exzellenzcluster Makromolekulare Komplexe (1)
- Helmholtz International Center for FAIR (1)
- Wirtschaftswissenschaften (1)
Nonequilibrium models (three-fluid hydrodynamics, UrQMD, and quark molecular dynamics) are used to discuss the uniqueness of often proposed experimental signatures for quark matter formation in relativistic heavy ion collisions from the SPS via RHIC to LHC. It is demonstrated that these models - although they do treat the most interesting early phase of the collisions quite differently (thermalizing QGP vs. coherent color fields with virtual particles) -- all yield a reasonable agreement with a large variety of the available heavy ion data. Hadron/hyperon yields, including J/Psi meson production/suppression, strange matter formation, dileptons, and directed flow (bounce-off and squeeze-out) are investigated. Observations of interesting phenomena in dense matter are reported. However, we emphasize the need for systematic future measurements to search for simultaneous irregularities in the excitation functions of several observables in order to come close to pinning the properties of hot, dense QCD matter from data. The role of future experiments with the STAR and ALICE detectors is pointed out.
Elliptic flow from nuclear collisions is a hadronic observable sensitive to the early stages of system evolution. We report first results on elliptic flow of charged particles at midrapidity in Au+Au collisions at sqrt(s_NN)=130 GeV using the STAR TPC at RHIC. The elliptic flow signal, v_2, averaged over transverse momentum, reaches values of about 6% for relatively peripheral collisions and decreases for the more central collisions. This can be interpreted as the observation of a higher degree of thermalization than at lower collision energies. Pseudorapidity and transverse momentum dependence of elliptic flow are also presented.
The adult human body contains about 4 g of iron. About 1–2 mg of iron is absorbed every day, and in healthy individuals, the same amount is excreted. We describe a patient who presents with severe iron deficiency anemia with hemoglobin levels below 6 g/dL and ferritin levels below 30 ng/mL. Although red blood cell concentrates and intravenous iron have been substituted every month for years, body iron stores remain depleted. Diagnostics have included several esophago-gastro-duodenoscopies, colonoscopies, MRI of the liver, repetitive bone marrow biopsies, psychological analysis, application of radioactive iron to determine intact erythropoiesis, and measurement of iron excretion in urine and feces. Typically, gastrointestinal bleeding is a major cause of iron loss. Surprisingly, intestinal iron excretion in stool in the patient was repetitively increased, without gastrointestinal bleeding. Furthermore, whole exome sequencing was performed in the patient and additional family members to identify potential causative genetic variants that may cause intestinal iron loss. Under different inheritance models, several rare mutations were identified, two of which (in CISD1 and KRI1) are likely to be functionally relevant. Intestinal iron loss in the current form has not yet been described and is, with high probability, the cause of the severe iron deficiency anemia in this patient.
Coordination of substitutionally inert [Ru(bpy)2]2+ fragments (bpy: 2,2′-bipyridine) to the a-iminoketone chelate ligands pyrazine-2-dimethylcarboxamide (4) and 4,7-phenanthroline-5,6-dione (5) yields the complexes [(N,O-4)Ru(bpy)2]2⊕, [(O,O′-5⊖)Ru(bpy)2]⊕ and {(N,O; N′,O′-5)[Ru(bpy)2]2}4⊕ which exhibit a rich electrochemistry. The distinctly different electronic structures of the complexes are evident from the ESR behaviour of paramagnetic intermediates: N.O-coordinated complexes have the unpaired electron residing in the ligand n system upon reduction, albeit with g<2 for the binuclear complex of 5. The paramagnetic O,O′-coordinated mononuclear complex with 5 has its redox potentials shifted positively relative to that of the binuclear system. These results are particularly noteworthy because 4 and 5 can be regarded as model compounds for the flavin and methoxatin dehydrogenase cofactors.
Background: Bipolar disorder is associated with circadian disruption and a high risk of suicidal behavior. In a previous exploratory study of patients with bipolar I disorder, we found that a history of suicide attempts was associated with differences between winter and summer levels of solar insolation. The purpose of this study was to confirm this finding using international data from 42% more collection sites and 25% more countries. Methods: Data analyzed were from 71 prior and new collection sites in 40 countries at a wide range of latitudes. The analysis included 4876 patients with bipolar I disorder, 45% more data than previously analyzed. Of the patients, 1496 (30.7%) had a history of suicide attempt. Solar insolation data, the amount of the sun’s electromagnetic energy striking the surface of the earth, was obtained for each onset location (479 locations in 64 countries). Results: This analysis confirmed the results of the exploratory study with the same best model and slightly better statistical significance. There was a significant inverse association between a history of suicide attempts and the ratio of mean winter insolation to mean summer insolation (mean winter insolation/mean summer insolation). This ratio is largest near the equator which has little change in solar insolation over the year, and smallest near the poles where the winter insolation is very small compared to the summer insolation. Other variables in the model associated with an increased risk of suicide attempts were a history of alcohol or substance abuse, female gender, and younger birth cohort. The winter/summer insolation ratio was also replaced with the ratio of minimum mean monthly insolation to the maximum mean monthly insolation to accommodate insolation patterns in the tropics, and nearly identical results were found. All estimated coefficients were significant at p < 0.01. Conclusion: A large change in solar insolation, both between winter and summer and between the minimum and maximum monthly values, may increase the risk of suicide attempts in bipolar I disorder. With frequent circadian rhythm dysfunction and suicidal behavior in bipolar disorder, greater understanding of the optimal roles of daylight and electric lighting in circadian entrainment is needed.
The results from the STAR Collaboration on directed flow (v1), elliptic flow (v2), and the fourth harmonic (v4) in the anisotropic azimuthal distribution of particles from Au+Au collisions at sqrt[sNN]=200GeV are summarized and compared with results from other experiments and theoretical models. Results for identified particles are presented and fit with a blast-wave model. Different anisotropic flow analysis methods are compared and nonflow effects are extracted from the data. For v2, scaling with the number of constituent quarks and parton coalescence are discussed. For v4, scaling with v22 and quark coalescence are discussed.
The microscopic phasespace approach URQMD is used to investigate the stopping power and particle production in heavy systems at SPS and RHIC energies. We find no gap in the baryon rapidity distribution even at RHIC. For CERN energies URQMD shows a pile up of baryons and a supression of multi-nucleon clusters at midrapidity.
Introduction: Recommendations for venous thromboembolism and deep venous thrombosis (DVT) prophylaxis using graduated compression stockings (GCS) is historically based and has been critically examined in current publications. Existing guidelines are inconclusive as to recommend the general use of GCS.
Patients/Methods: 24 273 in-patients (general surgery and orthopedic patients) undergoing surgery between 2006 and 2016 were included in a retrospectively analysis from a single center. From January 2006 to January 2011 perioperative GCS was employed additionally to drug prophylaxis and from February 2011 to March 2016 patients received drug prophylaxis alone. According to german guidelines all patients received venous thromboembolism prophylaxis with weight-adapted LMWH. Risk stratification (low risk, moderate risk, high risk) was based on the guideline of the American College of Chest Physicians. Data analysis was performed before and after propensity matching (PM). The defined primary endpoint was the incidence of symptomatic or fatal pulmonary embolism (PE). A secondary endpoint was the incidence of deep venous thromboembolism (DVT).
Results: After risk stratification (low risk n = 16 483; moderate risk n = 4464; high risk n = 3326) a total of 24 273 patient were analyzed. Before to PM the relative risk for the occurrence of a PE or DVT was not increased by abstaining from GCS. After PM two groups of 11 312 patients each, one with and one without GCS application, were formed. When comparing the two groups, the relative risk (RR) for the occurrence of a pulmonary embolism was: Low Risk 0.99 [CI95% 0.998–1.000]; Moderate Risk 0.999 [CI95% 0.95–1.003]; High Risk 0.996 [CI95% 0.992–1.000] (p > 0.05). The incidence of PE in the total group LMWH alone was 0.1% (n = 16). In the total group using LMWH + GCS, the incidence was 0.3% (n = 29). RR after PM was 0.999 [CI95% 0.998–1.00].
Conclusion: In comparison to prior studies with only small numbers of patients our trial shows in a large group of patients with moderate and high risk developing VTE we can support the view that abstaining from GCS-use does not increase the incidence of symptomatic or fatal PE and symptomatic DVT.
In context of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), patients with certain comorbidities and high age, as well as male sex are considered to represent the risk group for severe course of disease. Corona-virus disease 2019 (COVID-19) typical CT-patterns include bilateral, peripheral ground glass opacity (GGO), septal thickening, bronchiectasis, consolidation as well as associated pleural effusion. We report a 77-year-old heart transplanted patient with confirmed COVID-19 infection and coronary heart disease, diabetes type II and other risk factors. Notably, only slight clinical symptoms were reported and repeated computed tomography (CT) scans showed an atypical course of CT findings during his hospitalization.
Highlights
• MRI and ultrasound provided significant correlations between findings suggestive of vasculitis and the final diagnosis.
• Careful selection of available imaging techniques is warranted considering the time course, location, and clinical history.
• Considering its moderate diagnostic power to distinguish tracer uptake, a holistic view of PET/CT findings is essential.
Abstract
Purpose: To assess the diagnostic value of different imaging modalities in distinguishing systemic vasculitis from other internal and immunological diseases.
Methods: This retrospective study included 134 patients with suspected vasculitis who underwent ultrasound, magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) between 01/2010 and 01/2019, finally consisting of 70 individuals with vasculitis. The main study parameter was the confirmation of the diagnosis using one of the three different imaging modalities, with the adjudicated clinical and histopathological diagnosis as the gold standard. A secondary parameter was the morphological appearance of the vessel affected by vasculitis.
Results: Patients with systemic vasculitis had myriad clinical manifestations with joint pain as the most common symptom. We found significant correlations between different imaging findings suggestive of vasculitis and the final adjudicated clinical diagnosis. In this context, on MRI, vessel wall thickening, edema, and diameter differed significantly between vasculitis and non-vasculitis groups (p < 0.05). Ultrasound revealed different findings that may serve as red flags in identifying patients with vasculitis, such as vascular occlusion or halo sign (p = 0.02 vs. non-vasculitis group). Interestingly, comparing maximal standardized uptake values from PET/CT examinations with vessel wall thickening or vessel diameter did not result in significant differences (p > 0.05).
Conclusions: We observed significant correlations between different imaging findings suggestive of vasculitis on ultrasound or MRI and the final adjudicated diagnosis. While ultrasound and MRI were considered suitable imaging methods for detecting and discriminating typical vascular changes, 18F-FDG PET/CT requires careful timing and patient selection given its moderate diagnostic accuracy.
This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95–23.01) to 2.36 μSv (IQR, 0.52–12.66) (−36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 μSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 μSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (−30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.
Objectives: To assess the impact of noise-optimised virtual monoenergetic imaging (VMI+) on image quality and diagnostic evaluation in abdominal dual-energy CT scans with impaired portal-venous contrast.
Methods: We screened 11,746 patients who underwent portal-venous abdominal dual-energy CT for cancer staging between 08/2014 and 11/2019 and identified those with poor portal-venous contrast.
Standard linearly-blended image series and VMI+ image series at 40, 50, and 60 keV were reconstructed. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of abdominal organs and vascular structures were calculated. Image noise, image contrast and overall image quality were rated by three radiologists using 5-point Likert scale.
Results: 452 of 11,746 (4%) exams were poorly opacified. We excluded 190 cases due to incomplete datasets or multiple exams of the same patient with a final study group of 262. Highest CNR values in all abdominal organs (liver, 6.4 ± 3.0; kidney, 17.4 ± 7.5; spleen, 8.0 ± 3.5) and vascular structures (aorta, 16.0 ± 7.3; intrahepatic vein, 11.3 ± 4.7; portal vein, 15.5 ± 6.7) were measured at 40 keV VMI+ with significantly superior values compared to all other series. In subjective analysis, highest image contrast was seen at 40 keV VMI+ (4.8 ± 0.4), whereas overall image quality peaked at 50 keV VMI+ (4.2 ± 0.5) with significantly superior results compared to all other series (p < 0.001).
Conclusions: Image reconstruction using VMI+ algorithm at 50 keV significantly improves image contrast and image quality of originally poorly opacified abdominal CT scans and reduces the number of non-diagnostic scans.
Advances in knowledge: We validated the impact of VMI+ reconstructions in poorly attenuated DECT studies of the abdomen in a big data cohort.
Purpose: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model.
Methods: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation.
Results: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon.
Conclusions: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair.
The STAR Collaboration at the Relativistic Heavy Ion Collider presents measurements of 𝐽/𝜓→𝑒+𝑒− at midrapidity and high transverse momentum (𝑝𝑇>5 GeV/𝑐) in 𝑝+𝑝 and central Cu+Cu collisions at √𝑠𝑁𝑁=200 GeV. The inclusive 𝐽/𝜓 production cross section for Cu+Cu collisions is found to be consistent at high 𝑝𝑇 with the binary collision-scaled cross section for 𝑝+𝑝 collisions. At a confidence level of 97%, this is in contrast to a suppression of 𝐽/𝜓 production observed at lower 𝑝𝑇. Azimuthal correlations of 𝐽/𝜓 with charged hadrons in 𝑝+𝑝 collisions provide an estimate of the contribution of 𝐵-hadron decays to 𝐽/𝜓 production of 13%±5%.
We study the beam-energy and system-size dependence of \phi meson production (using the hadronic decay mode \phi -- K+K-) by comparing the new results from Cu+Cu collisions and previously reported Au+Au collisions at \sqrt{s_NN} = 62.4 and 200 GeV measured in the STAR experiment at RHIC. Data presented are from mid-rapidity (|y|<0.5) for 0.4 < pT < 5 GeV/c. At a given beam energy, the transverse momentum distributions for \phi mesons are observed to be similar in yield and shape for Cu+Cu and Au+Au colliding systems with similar average numbers of participating nucleons. The \phi meson yields in nucleus-nucleus collisions, normalised by the average number of participating nucleons, are found to be enhanced relative to those from p+p collisions with a different trend compared to strange baryons. The enhancement for \phi mesons is observed to be higher at \sqrt{s_NN} = 200 GeV compared to 62.4 GeV. These observations for the produced \phi(s\bar{s}) mesons clearly suggest that, at these collision energies, the source of enhancement of strange hadrons is related to the formation of a dense partonic medium in high energy nucleus-nucleus collisions and cannot be alone due to canonical suppression of their production in smaller systems.