Refine
Year of publication
Document Type
- Preprint (704)
- Article (384)
- Conference Proceeding (4)
- Book (1)
- Working Paper (1)
Has Fulltext
- yes (1094)
Is part of the Bibliography
- no (1094)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (10)
- Heavy-ion collision (6)
- Kollisionen schwerer Ionen (5)
- heavy ion collisions (5)
- ALICE experiment (4)
- Collective Flow (4)
- Jets (4)
Institute
- Physik (1077)
- Frankfurt Institute for Advanced Studies (FIAS) (957)
- Informatik (922)
- Medizin (14)
- Hochschulrechenzentrum (3)
- Informatik und Mathematik (3)
- Geowissenschaften (2)
- Starker Start ins Studium: Qualitätspakt Lehre (2)
- Biowissenschaften (1)
- Buchmann Institut für Molekulare Lebenswissenschaften (BMLS) (1)
- Helmholtz International Center for FAIR (1)
We study the thermodynamic properties of infinite nuclear matter with the Ultrarelativistic Quantum Molecular Dynamics (URQMD), a semiclassical transport model, running in a box with periodic boundary conditions. It appears that the energy density rises faster than T4 at high temperatures of T approx. 200 - 300 MeV. This indicates an increase in the number of degrees of freedom. Moreover, We have calculated direct photon production in Pb+Pb collisions at 160 GeV/u within this model. The direct photon slope from the microscopic calculation equals that from a hydrodynamical calculation without a phase transition in the equation of state of the photon source.
Nonequilibrium models (three-fluid hydrodynamics, UrQMD, and quark molecular dynamics) are used to discuss the uniqueness of often proposed experimental signatures for quark matter formation in relativistic heavy ion collisions from the SPS via RHIC to LHC. It is demonstrated that these models - although they do treat the most interesting early phase of the collisions quite differently (thermalizing QGP vs. coherent color fields with virtual particles) -- all yield a reasonable agreement with a large variety of the available heavy ion data. Hadron/hyperon yields, including J/Psi meson production/suppression, strange matter formation, dileptons, and directed flow (bounce-off and squeeze-out) are investigated. Observations of interesting phenomena in dense matter are reported. However, we emphasize the need for systematic future measurements to search for simultaneous irregularities in the excitation functions of several observables in order to come close to pinning the properties of hot, dense QCD matter from data. The role of future experiments with the STAR and ALICE detectors is pointed out.
Objective: Most patients suffering with rheumatic diseases who undergo surgical treatment are receiving immune-modulating therapy. To determine whether these medications affect their outcomes a national registry was established in Germany by the German Society of Surgery (DGORh). Data from the first 1000 patients were used in a pilot study to identify relevant corisk factors and to determine whether such a registry is suitable for developing accurate and relevant recommendations.
Design and participants: Data were collected from patients undergoing surgical treatments with their written consent. A second consent form was used, if complications occurred. During this pilot study, in order to obtain a quicker overview, risk factors were considered only in patients with complications. Only descriptive statistical analysis was employed in this pilot study due to limited number of observed complications and inhomogeneous data regarding the surgery and the medications the patients received. Analytical statistics will be performed to confirm the results in a future outcome study.
Results: Complications occurred in 26 patients and were distributed equally among the different types of surgeries. Twenty one of these patients were receiving immune-modulating therapy at the time, while five were not. Infections were observed in 2.3% of patients receiving and in 5.1% not receiving immunosuppression.
Conclusions: Due to the low number of cases, inhomogeneity in the diseases and the treatments received by the patients in this pilot study, it is not possible to develop standardised best-practice recommendations to optimise their care. Based on this observation we conclude that in order to be suitable to develop accurate and relevant recommendations a national registry must include the most important and relevant variables that impact the care and outcomes of these patients.
Background: Reports of head and neck ultrasound examinations are frequently written by hand as free texts. Naturally, quality and structure of free text reports is variable, depending on the examiner’s individual level of experience. Aim of the present study was to compare the quality of free text reports (FTR) and structured reports (SR) of head and neck ultrasound examinations.
Methods: Both standard FTRs and SRs of head and neck ultrasound examinations of 43 patients were acquired by nine independent examiners with comparable levels of experience. A template for structured reporting of head and neck ultrasound examinations was created using a web-based approach. FTRs and SRs were evaluated with regard to overall quality, completeness, required time to completion, and readability by four independent raters with different specializations (Paired Wilcoxon test, 95% CI) and inter-rater reliability was assessed (Fleiss’ kappa). A questionnaire was used to compare FTRs vs. SRs with respect to user satisfaction (Mann-Whitney U test, 95% CI).
Results: By comparison, completeness scores of SRs were significantly higher than FTRs’ completeness scores (94.4% vs. 45.6%, p < 0.001), and pathologies were described in more detail (91.1% vs. 54.5%, p < 0.001). Readability was significantly higher in all SRs when compared to FTRs (100% vs. 47.1%, p < 0.001). The mean time to complete a report, however, was significantly higher in SRs (176.5 vs. 107.3 s, p < 0.001). SRs achieved significantly higher user satisfaction ratings (VAS 8.87 vs. 1.41, p < 0.001) and a very high inter-rater reliability (Fleiss’ kappa 0.92).
Conclusions: As compared to FTRs, SRs of head and neck ultrasound examinations are more comprehensive and easier to understand. On the balance, the additional time needed for completing a SR is negligible. Also, SRs yield high inter-rater reliability and may be used for high-quality scientific data analyses.
The transverse mass mt distributions for deuterons and protons are measured in Pb+Pb reactions near midrapidity and in the range 0<mt–m<1.0 (1.5) GeV/c2 for minimum bias collisions at 158A GeV and for central collisions at 40 and 80 A GeV beam energies. The rapidity density dn/dy, inverse slope parameter T and mean transverse mass <mt> derived from mt distributions as well as the coalescence parameter B2 are studied as a function of the incident energy and the collision centrality. The deuteron mt spectra are significantly harder than those of protons, especially in central collisions. The coalescence factor B2 shows three systematic trends. First, it decreases strongly with increasing centrality reflecting an enlargement of the deuteron coalescence volume in central Pb+Pb collisions. Second, it increases with mt. Finally, B2 shows an increase with decreasing incident beam energy even within the SPS energy range. The results are discussed and compared to the predictions of models that include the collective expansion of the source created in Pb+Pb collisions.
The energy dependence of multiplicity fluctuations was studied for the most central Pb+Pb collisions at 20A, 30A, 40A, 80A and 158A GeV by the NA49 experiment at the CERN SPS. The multiplicity distribution for negatively and positively charged hadrons is significantly narrower than Poisson one for all energies. No significant structure in energy dependence of the scaled variance of multiplicity fluctuations is observed. The measured scaled variance is lower than the one predicted by the grand-canonical formulation of the hadron-resonance gas model. The results for scaled variance are in approximate agreement with the string-hadronic model UrQMD.
The microscopic phasespace approach URQMD is used to investigate the stopping power and particle production in heavy systems at SPS and RHIC energies. We find no gap in the baryon rapidity distribution even at RHIC. For CERN energies URQMD shows a pile up of baryons and a supression of multi-nucleon clusters at midrapidity.
Purpose: To identify transjugular intrahepatic portosystemic shunt (TIPS) thrombosis in abdominal CT scans applying quantitative image analysis.
Materials and methods: We retrospectively screened 184 patients to include 20 patients (male, 8; female, 12; mean age, 60.7 ± 8.87 years) with (case, n = 10) and without (control, n = 10) in-TIPS thrombosis who underwent clinically indicated contrast-enhanced and unenhanced abdominal CT followed by conventional TIPS-angiography between 08/2014 and 06/2020. First, images were scored visually. Second, region of interest (ROI) based quantitative measurements of CT attenuation were performed in the inferior vena cava (IVC), portal vein and in four TIPS locations. Minimum, maximum and average Hounsfield unit (HU) values were used as absolute and relative quantitative features. We analyzed the features with univariate testing.
Results: Subjective scores identified in-TIPS thrombosis in contrast-enhanced scans with an accuracy of 0.667 – 0.833. Patients with in-TIPS thrombosis had significantly lower average (p < 0.001), minimum (p < 0.001) and maximum HU (p = 0.043) in contrast-enhanced images. The in-TIPS / IVC ratio in contrast-enhanced images was significantly lower in patients with in-TIPS thrombosis (p < 0.001). No significant differences were found for unenhanced images. Analyzing the visually most suspicious ROI with consecutive calculation of its ratio to the IVC, all patients with a ratio < 1 suffered from in-TIPS thrombosis (p < 0.001, sensitivity and specificity = 100%).
Conclusion: Quantitative analysis of abdominal CT scans facilitates the stratification of in-TIPS thrombosis. In contrast-enhanced scans, an in-TIPS / IVC ratio < 1 could non-invasively stratify all patients with in-TIPS thrombosis.